Description
The FAAC 455 D is a reliable control panel which can power one or two operators. Also includes signaling status via display.
Can be used with the FAAC 390 230v operator, the FAAC 413 230v LS version, the FAAC 415 230v LS version operator and the FAAC 412 230v operator.
Technical Specifications
Power supply voltage | 230 Vac (+6% -10%) - 50 Hz |
Absorbed power | 10 W |
Motor max. load | 800 W |
Accessories max. load | 500 mA |
Electric lock max. load | 15 VA |
Operating ambient temperature | -20 °C to +55 °C |
Protection fuses |
2 |
Terminal board inputs | Open/Open free leaf/Stop (closed)/Opening safety devices/Closing safety devices/power supply+earth/opening and closing limit switches (gatecoder) |
Terminal board outputs | Flashing lamp/motors/24 Vdc power supply accessories/24Vdc Indicator light/fail safe/12 Vac electric lock power supply |
Rapid connector | Decoding cards/RP card receivers |
Status signalling | via display |
Functions (programming by display and push-buttons)
Function logics | Semi-automatic / Automatic / Safety / "stepped" semi-automatic / "stepped" automatic / "stepped" safety / Semi-automatic B / "Dead man" C |
Open and closing time | Programmable (0 to 120 s) |
Pause time | Programmable (0 to 4 min.) |
Closing leaf delay | Programmable (0 to 4 min.) |
Thrust power | Adjustable on 50 levels for each motor |
Work times learning (0 to 120 s) | Simple (work time self-learning of both leafs simultaneously). Complete (work time "manual" learning of each leaf with possibility to activate timed travel limit "decelerations") |
Deceleraetion | timed / with limit switch / with gatecoder |
Advanced programming | |
Maximum torque at initial thrust | Selectable (useful for heavy-weight leafs) |
Final stroke on closing | Selectable (makes the locking of the electric lock easier) |
Reversing stroke | Selectable (makes the release of the electric lock easier) |
Pre-flashing | 5 s (selectable) |
Opening leaf delay | 2 s (can be disabled) |
Closing photocell logic | Reverses on release/reverses immediately |
Fail safe (photocell test) | Selectable |
Electric lock on second leaf | Selectable |
Cycle count | Selectable (updating of a "count-down" - max. setting 99.000 thousand cycles) |
Service request | Selectable (when the numbers of cycles set by program is "reached", the system activates a preflashing of 8 s before every opening movement) |
Indicator light/timed output | Selectable (the indicator light output can also be used as a timed output - max 4 min.) |